Nanjing
Clover Medical Technology Co., Ltd.
Tel: +8625-8461-0201
Fax: +8625-8461-0406
Web:
www.clover-medical.net
Email:
cloverincinerator@Gmail.com
Skype: Clover-Incinerator
中文
Русский
Request Dealer
Incinerator
InstallationNew
Small Incinerators
Medical Incinerators
Pet Crematory
Sitemap
Contact
Us
Medical Incinerators
※
Model YD-30 Incinerator
※
Model YD-50 Incinerator
※
Model YD-100 Incinerator
※
Model YD-150 Incinerator
※
Model YD-300 Incinerator
※
Model YD-500 Incinerator
Small Incinerators
※
Model YD-15C Incinerator
※
Model YD-20C Incinerator
※
Model YD-30C Incinerator
Pet Crematory
※
Model SYC-50 Incinerator
※
Model SYC-100 Incinerator
※
Model A360 Animal Cremator
※
Model A600 Animal
Cremator
※
Model A900 Animal
Cremator
※
Model A1200 Animal
Cremator
※
Model A1500 Animal
Cremator
※
Model A2400 Animal
Cremator
※
Model A4000 Animal
Cremator
Economical Incinerators
※
Model YZ-20 Incinerator
※
Model YZ-50 Incinerator
※
Model YZ-100 Incinerator
※
Model YZ-150 Incinerator
>Small
Incinerator
>Large
Incinerator
>W2E
Incinerator
Pet Crematory
50kgs per hour
New
Burn Rate(Kgs/hour)
10kg capacity Incinerator
20kg capacity Incinerator
30kg capacity Incinerator
50kg capacity Incinerator
100kg
capacity Incinerator
150kg
capacity Incinerator
300kg capacity Incinerator
500kg capacity Incinerator
>Sterilization
System
>Light
Oil Burner
>Gas
Burner
>Burners
>Vacuum
Cleaner
>Incinerator
FAQ (PDF)
>Company
Brief(PDF)
>How
to Buy
>Photo
Gallery
>Certificate
>What's
New
|
Model YD-20C
Incinerator
Equipment Technical Specifications |
Model |
YD-20C |
Feed Capacity |
40-80 kgs per feed |
Burning Rate |
20 kgs per hour |
Burning Time per Feed |
2.0-4.0 hours |
Voltage |
220V |
Power |
0.50Kw |
Fuel |
Natural Gas or Diesel oil |
Burner |
Italy Burner |
Feed Mode |
Manual |
Fuel consumption (Oil) |
5.4-12.6 Kgs/Hour |
Fuel consumption (Gas) |
6.5-15.0m3/Hour |
External Dimensions |
170 x 140 x 160cm (mainbody) |
Internal Dimensions |
55 x 55 x 65cm(Primary Chamber) |
Waste combustion chamber |
200Liters |
Post Combustion Chamber |
140Liters |
Oil Tank Capacity |
100 Liters |
Door Opening |
38 x 48cm |
Chimney |
5.0M |
Gross Weight |
1200kgs |
Chamber Material |
Refractory Concrete |
Max. Heat Value |
126,000Kcal/Hr. |
Operation Technical Specifications |
Solid Chamber temperature |
8000C -10000C |
Gas Chamber temperature |
10000C -12000C |
Chamber Anti-Rate
|
13500C |
Residency time
|
2.0 Sec. |
Burning efficiency |
>98% |
Waste Lower Calorific Power |
3000Kcal |
medical
incinerators medical incinerator supplies medical incinerator italy
medical incinerator china medical incinerator ce mark medical
incinerator buyer medical incinerator
medical incinerator medical incinerator medical incinerator
|
|