Animal Crematorium Incinerators Rated for 60 Pounds Per Hour

Product Description

Waste Incinerator International Market Analytics  Date.

Key Word:  Little incinerators  Medical waste incinerator  Pet animal cremation incinerator  Incinerator makers

Incinerator is a incineration gear, direct fire waste by gasoline fuel or oi gas. As distinct circumscription, incinerator could be termed many words as under: 

Therapy ability: Small scale incinerator, large scale incinerator and incineration pant.  Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators  Incinerator gas: Gas incinerator, petroleum incinerator  Waste to Energy (WTE): WTE incinerator, non-WTE incinerator  Incinerator Manufacturer: China incinerator maker, UK incinerator producer, USA incinerator producer, India incinerator manufacturer.  Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)  Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is traditional waste treatment solution for many years. All over the world, in most nations, people anti incinerator since the incinerator will produce a sizable Dioxin from the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins could be released to the environment through forest fires, backyard burning of garbage, certain industrial activities, and residue from beyond business burning of waste. Dioxins break down very slowly and previous releases of dioxins from both natural and man-made sources still exist from the environment. Anyhow, we have to remind this, that is large scale incineration pant, normally more than 30 ton daily. This is a social issue, to examine and indicate ways in different angles from the public, government, economic development, environmental protection, technology advancement, etc. 

So, why we still use incinerator?  First, for your medical waste in the hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can ruin the virus, pollution control.  Second, for human body, pet creature, in most nations and regions, we desire to cremation them. This is the ceremony in the procedure for society development, and ceremonies to commemorate the disappearance of existence. 

As previously two reason but not just above, we nevertheless use incinerators. 

the way you are able to find reasonable incinerator to your regional website?  Incinerator is not a cheap equipment, normally the little scale model’s price around $5, 000USD per unit and large scale model’s price more than $50, 000USD per unit. Thus, before purchase one unit incinerator, you need to make clear after items: A, burn what? Incinerator is a incineration gear, function is fire waste. So what kind of waste you would like to treatment?  B, little or large? This based on the waste output daily or the waste volume per feed period, like creature size.  Incinerator use gas or oil fuel, normally, syc-10 incinerator, thermal oxidiser maker, two chamber medical waste incinerator, waste incineration china, waste incineration furnace, waste incineration in china, gasoline fuel is cheaper than oil along with also the smoke cleaner than petroleum fuel model. However, some local website don’t have gasoline supply system.  Along with other technology items, like electricity (220V, 380V), waste feed doorway kind, incinerator construction, etc. 

After you clarify these, you can go to find a local or global producers, asking prices, technical specifications and finally purchasing the right products. 

Items/Model YD-30 YD-50 YD-100 YD-150 Items/Model YD-200 YD-300 YD-500 YD-600 Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr. Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 360 900 1200 1500 Primary Chamber (Liters) 2000 2400 4000 5500 Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 200 200 500 500 Secondary Chamber (Liters) 500 1200 1500 1500 Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475 External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125 Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 200 300 300 500 Oil Tank(Liters) 300 500 500 500 Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128 Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 5 10 10 Chimney (M) 10 10 14 14 Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES Temperature Monitoring YES YES YES