Burner Performance feature
Al-in-one blower.
Auto-operation
Manual switch for one stage/two stage
Gas auto-leakage(option)double solenoid valve (single vafive for one
stage)
Protect for the gas pressure ensure to stop burner running when the gas
pressure is too high or too low.
Protect for the air pressure ensure to stop burner running when the air
pressure is too low.
Sweep the tube before ignition.
Safety flame monitors system.
The servo motor will close the air gate when stop the burner.(manual
adjust the air gate for one stage)
The servo motor moves the camto control the air gate and the gas
butterfly valve which adjusting the consumption of air and gas.(For
modulating & Sliding series)
Convenient for the installation,commissioning and maintenance because
the gemel connection between the burners body and tube
The burner is easy to install for the portable body,The client just
connects the power supply and gas suply and gas supply then can start
the burner.
The little running noise and the discharge gas can suitable for the
demands of the environmental protection.
Can suitable different kind of fuel gas.
The standard collocate Electric protect grade is IP40.
Burner
Operation
BT...GF On-off
BT...GRF HI-LOW with servo motor
BT...GS/M Sliding/Modulting with servo motor
Gas Burner - One-Stage |
Gas Burner - Modulating Gas Burner |
Model |
Output max.(Kw) |
Output min.(Kw) |
Model |
Output max.(Kw) |
Output min.(Kw) |
BT3GF |
41.9 |
16.3 |
BT17GS/M |
168 |
50 |
BT6GF |
56.3 |
30.6 |
BT35GS/M |
340 |
60 |
BT11GF |
99 |
48.8 |
BT40GS/M |
425 |
185 |
BT17GF |
168 |
69 |
BT60GS/M |
738 |
248 |
BT20GF |
200 |
50 |
BT100GS/M |
995 |
280 |
BT30GF |
300 |
60 |
BT120GS/M |
1200 |
350 |
BT35GF |
358 |
90 |
BT150GS/M |
1428 |
414 |
BT50GF |
596 |
169 |
BT200GS/M |
2000 |
490 |
BT60GF |
738 |
248 |
BT250GS/M |
2500 |
590 |
Gas Burner - TWO-Stage |
BT350GS/M |
3500 |
924 |
Model |
Output max.(Kw) |
Output min.(Kw) |
BT400GS/M |
3800 |
924 |
BT17GRF |
168 |
69 |
BT450GS/M |
4000 |
550 |
BT20GRF |
200 |
50 |
BT550G S/M |
5400 |
600 |
BT30GRF |
300 |
60 |
BT650G S/M |
7400 |
800 |
BT35GRF |
358 |
90 |
BT1000G S/M |
10500 |
1000 |
BT40GRF |
425 |
185 |
Gas Burner - Coal-gas-burner |
BT60GRF |
738 |
248 |
Model |
Output max.(Kw) |
Output min.(Kw) |
BT100GRF |
995 |
280 |
BT11TGF |
109 |
48 |
BT120GRF |
1200 |
350 |
BT17TGF |
150 |
69 |
BT150GRF |
1428 |
414 |
BT30TGF |
208.8 |
101 |
BT200GRF |
2000 |
490 |
BT40TGF |
320 |
186 |
BT250GRF |
2500 |
590 |
BT60TGF |
465 |
184 |
BT300GRF |
2982 |
657 |
BT30TGF |
208.8 |
101 |
BT350GRF |
3500 |
924 |
BT35TGF |
279 |
128 |
BT400GRF |
3950 |
924 |
BT40TGF |
320 |
186 |
Model |
Specification |
BT60TGF |
465 |
184 |
TC-10G |
OFF-ON, Output(10Kcal/H):1-2 |
BT100TGF |
755 |
355 |
TC-30G |
OFF-ON,
Output(10Kcal/H):3 |
BT150TGF |
1451 |
653 |
GOM-2 |
OFF-ON,
Output(10Kcal/H):12 |
BT250TGF |
2362 |
715 |
GOM-3 |
OFF-ON,
Output(10Kcal/H):20 |
|
|
|
AG-100 |
Two stage,
Output(10Kcal/H):80 |
|
|
|
|