		 Burner Performance feature 
		Al-in-one blower. 
		Auto-operation 
		Manual switch for one stage/two stage 
		Gas auto-leakage(option)double solenoid valve (single vafive for one 
		stage) 
		Protect for the gas pressure ensure to stop burner running when the gas 
		pressure is too high or too low. 
		Protect for the air pressure ensure to stop burner running when the air 
		pressure is too low. 
		Sweep the tube before ignition. 
		Safety flame monitors system. 
		The servo motor will close the air gate when stop the burner.(manual 
		adjust the air gate for one stage) 
		The servo motor moves the camto control the air gate and the gas 
		butterfly valve which adjusting the consumption of air and gas.(For 
		modulating & Sliding series) 
		Convenient for the installation,commissioning and maintenance because 
		the gemel connection between the burners body and tube 
		The burner is easy to install for the portable body,The client just 
		connects the power supply and gas suply and gas supply then can start 
		the burner. 
		The little running noise and the discharge gas can suitable for the 
		demands of the environmental protection. 
		Can suitable different kind of fuel gas. 
		The standard collocate Electric protect grade is IP40. 
		 
		Burner
		Operation 
		 
		BT...GF On-off 
		BT...GRF HI-LOW with servo motor 
		BT...GS/M Sliding/Modulting with servo motor 
		 
 
		
			
				
				
				
				
				
				
			
			
				| 
				Gas Burner - One-Stage | 
				
				Gas Burner - Modulating Gas Burner | 
			 
			
				| 
				 Model | 
				
				Output max.(Kw) | 
				
				Output min.(Kw) | 
				
				 Model | 
				
				Output max.(Kw) | 
				
				Output min.(Kw) | 
			 
			
				| 
				 BT3GF | 
				
				41.9 | 
				
				16.3 | 
				
				 BT17GS/M | 
				
				168 | 
				
				50 | 
			 
			
				| 
				 BT6GF | 
				
				56.3 | 
				
				30.6 | 
				
				 BT35GS/M | 
				
				340 | 
				
				60 | 
			 
			
				| 
				 BT11GF | 
				
				99 | 
				
				48.8 | 
				
				 BT40GS/M | 
				
				425 | 
				
				185 | 
			 
			
				| 
				 BT17GF | 
				
				168 | 
				
				69 | 
				
				 BT60GS/M | 
				
				738 | 
				
				248 | 
			 
			
				| 
				 BT20GF | 
				
				200 | 
				
				50 | 
				
				 BT100GS/M | 
				
				995 | 
				
				280 | 
			 
			
				| 
				 BT30GF | 
				
				300 | 
				
				60 | 
				
				 BT120GS/M | 
				
				1200 | 
				
				350 | 
			 
			
				| 
				 BT35GF | 
				
				358 | 
				
				90 | 
				
				 BT150GS/M | 
				
				1428 | 
				
				414 | 
			 
			
				| 
				 BT50GF | 
				
				596 | 
				
				169 | 
				
				 BT200GS/M | 
				
				2000 | 
				
				490 | 
			 
			
				| 
				 BT60GF | 
				
				738 | 
				
				248 | 
				
				 BT250GS/M | 
				
				2500 | 
				
				590 | 
			 
			
				| 
				Gas Burner - TWO-Stage | 
				
				 BT350GS/M | 
				
				3500 | 
				
				924 | 
			 
			
				| 
				 Model | 
				
				Output max.(Kw) | 
				
				Output min.(Kw) | 
				
				 BT400GS/M | 
				
				3800 | 
				
				924 | 
			 
			
				| 
				 BT17GRF | 
				
				168 | 
				
				69 | 
				
				 BT450GS/M | 
				
				4000 | 
				
				550 | 
			 
			
				| 
				 BT20GRF | 
				
				200 | 
				
				50 | 
				
				 BT550G S/M | 
				
				5400 | 
				
				600 | 
			 
			
				| 
				 BT30GRF | 
				
				300 | 
				
				60 | 
				
				 BT650G S/M | 
				
				7400 | 
				
				800 | 
			 
			
				| 
				 BT35GRF | 
				
				358 | 
				
				90 | 
				
				 BT1000G S/M | 
				
				10500 | 
				
				1000 | 
			 
			
				| 
				 BT40GRF | 
				
				425 | 
				
				185 | 
				
				Gas Burner - Coal-gas-burner | 
			 
			
				| 
				 BT60GRF | 
				
				738 | 
				
				248 | 
				
				 Model | 
				
				Output max.(Kw) | 
				
				Output min.(Kw) | 
			 
			
				| 
				 BT100GRF | 
				
				995 | 
				
				280 | 
				
				 BT11TGF | 
				
				109 | 
				
				48 | 
			 
			
				| 
				 BT120GRF | 
				
				1200 | 
				
				350 | 
				
				 BT17TGF | 
				
				150 | 
				
				69 | 
			 
			
				| 
				 BT150GRF | 
				
				1428 | 
				
				414 | 
				
				 BT30TGF | 
				
				208.8 | 
				
				101 | 
			 
			
				| 
				 BT200GRF | 
				
				2000 | 
				
				490 | 
				
				 BT40TGF | 
				
				320 | 
				
				186 | 
			 
			
				| 
				 BT250GRF | 
				
				2500 | 
				
				590 | 
				
				 BT60TGF | 
				
				465 | 
				
				184 | 
			 
			
				| 
				 BT300GRF | 
				
				2982 | 
				
				657 | 
				
				 BT30TGF | 
				
				208.8 | 
				
				101 | 
			 
			
				| 
				 BT350GRF | 
				
				3500 | 
				
				924 | 
				
				 BT35TGF | 
				
				279 | 
				
				128 | 
			 
			
				| 
				 BT400GRF | 
				
				3950 | 
				
				924 | 
				
				 BT40TGF | 
				
				320 | 
				
				186 | 
			 
			
				| 
				Model | 
				
				Specification | 
				
				 BT60TGF | 
				
				465 | 
				
				184 | 
			 
			
				| 
				TC-10G | 
				
				OFF-ON, Output(10Kcal/H):1-2 | 
				
				 BT100TGF | 
				
				755 | 
				
				355 | 
			 
			
				| 
				
						TC-30G | 
				
				
						OFF-ON, 
				Output(10Kcal/H):3 | 
				
				 BT150TGF | 
				
				1451 | 
				
				653 | 
			 
			
				| 
						GOM-2 | 
				
						OFF-ON, 
				Output(10Kcal/H):12 | 
				
				 BT250TGF | 
				
				2362 | 
				
				715 | 
			 
			
				| 
						GOM-3 | 
				
						OFF-ON, 
				Output(10Kcal/H):20 | 
				
				  | 
				
				  | 
				
				  | 
			 
			
				| 
						AG-100 | 
				
						
						Two stage, 
				Output(10Kcal/H):80 | 
				
				  | 
				
				  | 
				
				  | 
			 
		 
		 |