Little Capacity Incineratorsmall 20 Kg/Hour Medical Waste Inc

Basic Info.

Model NO.:Slaughterhouse Waste Incinerator
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste may use within this gear?  A: This gear to medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Remedy capacity  A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time daily to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator involving 5-10 year according to use. 

Ordinarily, we proposition little laboratory, little clinic use capacity under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that’s imply you need one incinerator capacity around 400kgs per day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, funding, development, etc, you may use capacity from 30-50 kgs per hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Assembly and Testing  A: We supply all files and incinerators easy to installation and functionality. Customer can send people visit our factory to find out operation and installation. Generally, We do not send engineer to neighborhood website or even ask. The dispatch cost is extra according to order.  The next combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode  A: Default Control manner is common control instance. PLC mode according to model and order. 

Q: Operation and maintenance costs  A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD per year maintenance according version, use situation. 

One individual can service 02 unit incinerators. Incinerators italy for medical waste, incinerators medical waste, incinirator, industrial incinerators china, insenorator, klarge garden incinerator, lab animal incinerator auction, The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to functionality consumer guider, and understand risk of medical waste to safeguard worker self with necessary security element. 

Q: The Residency time in secondary combustion chamber  A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm